DAMPAK PEMBEBANAN KAPASITIF MURNI DAN RESISTIF KAPASITIF PADA PERUBAHAN VEKTOR GENERATOR SINKRON TIGA FASA

Dionysius Indra Widyasmara, Arifin Wibisono, Slamet Riyadi

Abstract


The development of electrical energy sources has been the primary focus in recent decades, driven by the increasing global demand for electricity. This phenomenon marks a global shift towards more sustainable and environmentally friendly energy sources. One key aspect of this development is related to various technologies in power generation, including synchronous generators. Synchronous generators play a crucial role in the electrical energy infrastructure due to their ability to produce power stably and efficiently, meeting the demand for reliable and high-quality electricity supply. In the context of the role of synchronous generators, it is important to understand how these generators react to variable capacitive loading. This capacitive loading can affect the overall efficiency and performance of the power generation system. In this situation, the influence of capacitive loading is particularly evident in the formation of reactive power. The reactive power generated can significantly affect the speed and frequency of synchronous generators. Furthermore, the effects of capacitive loading can also be felt in the voltage of the system. Voltage fluctuations may occur, often requiring compensation in the form of field current to maintain system stability. Therefore, a deep understanding of how synchronous generators respond to capacitive loading is crucial to ensuring optimal performance of the power generation system as a whole, as well as in formulating strategies to improve the efficiency and reliability of electrical energy in the future.             

 

Keywords: Capacitive, Excitation System, Resistive, Synchronous Generator.

 

ABSTRAK

Perkembangan sumber energi listrik telah menjadi fokus utama dalam beberapa dekade terakhir seiring dengan meningkatnya kebutuhan akan energi listrik di seluruh dunia. Fenomena ini menandai pergeseran global menuju sumber energi yang lebih berkelanjutan dan ramah lingkungan. Salah satu aspek utama dari perkembangan ini adalah terkait dengan berbagai teknologi dalam pembangkit listrik, di antaranya adalah generator sinkron. Generator sinkron memiliki peran penting dalam infrastruktur energi listrik karena kemampuannya untuk menghasilkan daya secara stabil dan efisien, memenuhi tuntutan masyarakat akan pasokan listrik yang andal dan berkualitas. Dalam konteks peran generator sinkron, penting untuk memahami bagaimana generator tersebut bereaksi terhadap pembebanan kapasitif yang variatif. Pembebanan kapasitif ini dapat memengaruhi efisiensi dan kinerja keseluruhan dari sistem pembangkit listrik. Dalam situasi ini, pengaruh dari pembebanan kapasitif terutama terlihat dalam pembentukan daya reaktif. Daya reaktif yang dihasilkan dapat mempengaruhi putaran dan frekuensi generator sinkron secara signifikan. Selain itu, efek dari pembebanan kapasitif juga dapat dirasakan pada tegangan dalam sistem. Fluktuasi tegangan dapat terjadi, yang sering kali memerlukan kompensasi dalam bentuk arus medan agar stabilitas sistem tetap terjaga. Oleh karena itu, pemahaman yang mendalam tentang bagaimana generator sinkron dengan pembebanan kapasitif menjadi sangat penting dalam memastikan kinerja yang optimal dari sistem pembangkit listrik secara keseluruhan, serta dalam merumuskan strategi untuk meningkatkan efisiensi dan keandalan energi listrik di masa depan.


Keywords


Generator Sinkron, Kapasitif, Resistif, Sistem Eksitasi

Full Text:

PDF

References


S. M. Toufighian, J. Faiz, dan A. Erfani-Nik, “Static Eccentricity Fault Detection in Salient and Non-Salient Synchronous Generators Using Harmonic Components,” in 2021 12th Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2021, Institute of Electrical and Electron-ics Engineers Inc., Feb. 2021.doi:10.1109/PEDSTC52094.2021.9405971

Institute of Electrical and Electronics Engineers. In-donesia Section and Institute of Electrical and Elec-tronics Engineers, 2019 International Conference on Information and Communications Technology. [Online]. https://ieeexplore.ieee.org/abstract/document/8938560

Annisa, Winarso, dan W. Dwianto, “Analisis Pengaruh Perubahan Beban Terhadap Karakteristik Generator Sinkron.” Jurnal Riset Rekayasa Elektro. vol. 1, no.1, hal. 37-53, 2019.

W. E. Vanco, F. B. Silva, C. M. R. De Oliveira, J. R. B. A. Monteiro, dan J. M. M. De Oliveira, “A Proposal of Expansion and Implementation in Isolated Gen-eration Systems Using Self-Excited Induction Gener-ator with Synchronous Generator,” IEEE Access, vol. 7, hal.117188–117195, 2019.

“58125-469-143600-1-10-20200307”.

A. Dan Simulasi Pengaruh Pemasangan dan A. Uli Ulya, “Menggunakan Simulink pada Sistem Tenaga Listrik di PT. Bogowonto Primalaras,” Media El-ektrika, vol. 12, no. 1, 2019, [Online]. Tersedia: http://jurnal.unimus.ac.id

D. Yaman, T. Hasanuddin, R. Tri Fahlevi, J. Teknik Elektro, dan P. Negeri Lhokseumawe, “Pengujian Daya Balik Pada Sinkronisasi Generator Dengan Sumber Daya Sangat Besar (Infinite Bus) Secara Otomatis Menggunakan Multifunction Relay Tipe GCP-30 di Laboratorium Sistem Proteksi,” DISTRIBUSI JURUSAN TEKNIK ELEKTRO, 2022, [Online]. Tersedia: https://download.garuda.kemdikbud.go.id/article.php?art cle=3408124&val=29910&title=Pengujian%20Daya%20Balik%20pada%20Sinkronisasi%20Generator%20dengan%20Sumber%20Daya%20Sangat%20Besar%20Infinite%20Bus%20secara%20Otomatis%20Menggunakan%20Multifunction%20Relay%20Tipe%20GCP-30%20di%20Laboratorium%20Sistem%20Proteksi%20dan%20Distribusi%20Jurusan%20Teknik%20Elektro

M. H. Basri, ELEMEN : JURNAL TEKNIK MESIN, vol. 7, no. 1, Jun. 2020, doi: 10.34128/je.v7i1.119. [Online]. Tersedia: https://download.garuda.kemdikbud.go.id/article.php?article=1732131&val=14206&title=PERANCANGAN%20GENERATOR%203-PHASE%20PADA%20GRAVITATION%20WATER%20VORTEX%20POWER%20PLANT%20GWVPP

M. Harahap, dkk., “Pengaruh Perubahan Variasi Eksitasi Tegangan Terhadap Daya Reaktif Pada Generator,” RELE, vol. 3, no. 2, hal. 71-76, 2021, doi: 10.30596/rele.v3i2.6485.

A. R. Lubis, A. Sutopo, dan M. Affandi, “Analisis Harmonisa Pada Trainer Lab Generator Sinkron Ti-ga Fasa NV7017,” JTEIN, vol. 4, no. 2, 2023, doi: 10.24036/jtein.v4i2.452.

K. C. Sindang, B. Mukhlis, dan Y. Arifin, “Pengaruh Pembebanan Terhadap Sistem Eksitasi Generator Sinkron Sf 33.065 Pada Pembangkit Listrik Tenaga Air (PLTA) Poso 1 Energy,” dalam SNTEI, 2022, hal. 393-397.

D. F. Nurjaman, “Analisis Pengaruh Sistem Eksitasi Terhadap Tegangan Keluaran Generator Sinkron Mini Hydro.” EPSILON, vol. 19, no. 3, hal. 85-88, 2021. doi: 10.55893/epsilon.v19i3.71

A. Zulhakim, Y. S. Handayani, dan I. Priyadi, “Pengaruh Sistem Eksitasi Terhadap Generator Sink-ron Tiga Fasa di Unit 1 PT. PLN Indonesia Power ULPL TA Musi,” Teknosia, vol. 17, no. 1, hal. 1–12, Jul. 2023.

P. E. Pambudi, M. Suyanto, dan D. S. Yogaswara, “Pengaruh Tegangan Eksitasi Terhadap output Te-gangan Generator Sinkron 3 Fasa 6,3kV”, Jurnal Teknologi, vol. 15, no. 2, hal.152–158, 2021.

F. Sari, dan A. Darwanto, “Analisis Sistem Eksitasi Pada Generator Pararel Terhadap Daya Reaktif”, Jurnal Teknologi, vol. 14, no. 1, hal.10–19, 2021.

Y. Esye, dan S. Lesmana, “Analisa Perbaikan Faktor Daya Sistem Kelistrikan” JST, vol. 11, no. 1, hal.103–113, 2021.

F. Baskoro, A. Nizar, and B. Suprianto, “Analisis Rugi Daya Menggunakan ETAP pada Jaringan Dis-tribusi 20kV Penyulang Bagong”, JTE, vol. 10, no. 1, hal. 195-201, 2020.




DOI: http://dx.doi.org/10.26623/elektrika.v16i1.8695

Refbacks

  • There are currently no refbacks.


Office: Electrical Engineering Lecturer Room, 7th Floor of Menara USM Building, Universitas Semarang, Jalan Soekarno - Hatta, Tlogosari, Semarang - Central Java Tel:(024) 6702757 Fax: (024) 6702272, Email: elektrika@usm.ac.id

View My Stats

Creative Commons License
This work is licensed under a  Creative Commons Attribution 4.0 International License.