ANALISA PENGARUH PERUBAHAN FREKUENSI DAN TEGANGAN TERHADAP EFISIENSI MOTOR INDUKSI TIGA FASA MENGGUNAKAN MATLAB SIMULINK

Sulis Diantoro, Dedi Nugroho, Agus Adhi Nugroho

Abstract


The three-phase induction motor is one of the most widely used types of electric motor in the industrial world. In its application to regulate the speed and improve the efficiency of the motor used the method of Variable frequency drive (VFD) by changing the input frequencies. The final task uses a simulated simulation method of the simulink matlab that will analyze the influence of frequency and voltage changes on speed, slip, and motor efficiency. The results show that frequency and voltage changes have an impact on induction motor performance that includes speed, slip, and efficiency. Often, they scream and shout. From a frequency of 50 Hz, every 10 percent decrease in the Frequency then the speed also decreases by about 10 percent. Frequencies of 50 Hz and 45 Hz produce speeds of 1440 rpm and 1295 rpm. For the slip, the increase in frequency leads to a decrease in the motor slip value. At the frequencies of 50 Hz and 45 Hz produced slide values of 4% and 16%. The highest efficiency is given at a torque load of 5 Nm and a frequency of 50 Hz with an efficiency of 97%.

Keywords: 3-phase induction engine, VFD, Matlab, Frequency, Speed, Slip, Efficiency

ABSTRAK

Motor induksi tiga fasa adalah salah satu jenis motor listrik yang paling banyak digunakan dalam dunia industri. Dalam penerapannya untuk mengatur kecepatan dan meningkatkan efisiensi motor digunakan metode Variable frequency drive (VFD) dengan mengubah frekuensi masukan. Penelitian ini menggunakan metode simulasi matlab simulink yang akan menganalisa mengenai pengaruh perubahan frekuensi dan tegangan terhadap kecepatan, slip, dan efisiensi motor. Hasil penelitian menunjukkan bahwa perubahan frekuensi dan tegangan mempunyai dampak terhadap kinerja motor induksi yang meliputi kecepatan, slip, dan efisiensi. Frekuensi berbanding lurus dengan kecepatan dan efisiensi. Dari frekuensi 50 Hz, setiap penurunan frekuensi 10% maka kecepatan juga turun sekitar 10%. Frekuensi 50 Hz dan 45 Hz menghasilkan kecepatan 1440 Rpm dan 1295 Rpm. Untuk slip, kenaikan frekuensi menyebabkan turunnya nilai slip motor. Pada frekuensi 50 Hz dan 45 Hz menghasilkan nilai slip 4% dan 16%. Sedangkan untuk nilai efisiensi tertinggi terjadi ketika diberi beban torsi 5 N.m dan frekuensi 50 Hz dengan efisiensi sebesar 97%.

Keywords


Motor Induksi 3 fasa, VFD, Matlab,Frekuensi, Kecepatan, Slip, Efisiensi

Full Text:

PDF

References


D. Kumar, “Performance analysis of three-phase induction motor with AC direct and VFD,” in IOP Conference Series: Materials Science and Engineering, 2018, vol. 331, no. 1, hlm. 12025.

D. Andri, “Analisa Perubahan Putaran Motor Induksi 3 Fasa Jenis Rotor Sangkar Tupai Dalam Keadaan Pembebanan dan Membandingkannya Dengan Program Matlab Simulink,” 2016.

A. Muhammad dkk., “Analisa Rugi-Rugi Energi Listrik Pada Jaringan Distribusi (JTM) Di PT. PLN (Persero) Area Gorontalo,” J. Tek. Elektro dan Komput., vol. 7, no. 3, hlm. 295– 302, 2019.

A. Kurnia Pratama, E. Zondra, and H. Yuvendius, “Analisis Efisiensi Motor Induksi Tiga Phasa Akibat Perubahan Tegangan,” J. Sain, Energi, Teknol. Ind., vol. 5, no. 1, pp. 35–43, 2020.

Z. Anthony, D. Jurusan, dan T. Elektro, “Studi Pengaruh Perubahan Frekwensi Sumber Terhadap Faktor Daya Motor Induksi 3-Fasa Jurnal Teknik Elektro ITP,” vol. 2, no. 2, hlm. 49– 52, 2013.

F. Y. Nanda, “Pengaruh Perubahan Frekuensi Terhadap Efisiensi Dan Torsi Pada Motor Induksi 3 Fase 0,25 Kw 380 Volt Di Pt Djarum Kudus,” 2019.

A. Puspitasari, “Analisa Distorsi Harmonik Pada Inverter Svpwm 3 Fasa Dengan Beban Induktif.” Universitas Islam Sultan Agung, 2019.

Zuhal, “Dasar Tenaga Listrik Dan Elektonika Daya.” hlm. 264, 2000.

B. Muslim, “Kendali Kecepatan Motor Induksi Tiga Fasa Menggunakan Kontroler Fuzzy-PID,” J. Tek. Elektro ITS, vol. 3, no. 1, hlm. 1–10, 2015.

I Nyoman Bagia & I Made Parsa, Motor-motor Listrik. 2018.

S. J. Chapman, “Electric Machinery Fundamentals,” Electr. Mach. Fundam. fourth Ed., vol. 6, no. August, hlm. 128, 2016.

M. M. Ibrahim, “Pengaturan Kecepatan Motor Induksi 3 Fasa Dengan Metode V/F Konstan Dan Kontrol PID-CHR,” Energi & Kelistrikan, vol. 14, no. 1, hlm. 62–71, 2022, doi: 10.33322/energi.v14i1.1632.

K. H. Ahmed, S. J. Finney, and B. W. Williams, “Passive Filter Design for Three-Phase Inverter Interfacing in Distributed Generation,” in 2007 Compatibility in Power Electronics, 2007, hlm. 1–9. doi: 10.1109/CPE.2007.4296511.

M. Ali, “Aplikasi Elektronika Daya pada Sistem Tenaga Listrik,” UNY Pers, hlm. 1–149, 2018.

T. L. Wibowo, J. T. Elektro, dan F. T. Industri, “Penghematan Energi Pada Penggunaan Inverter Sebagai Pengendal Kecepatan Motor Induksi,” vol. 1, no. 1, hlm. 1–8, 2010.

A. D. Baringbing, “Analisa Performa Motor Induksi Tiga Fasa Dengan Variable Frequency Drive (VFD) Menggunakan Pulse Generator Pwm Dan Svpwm,” hlm. 198, 2022.

H. D. Laksono, Pengantar Pemrograman Dengan Matlab. 2017.




DOI: http://dx.doi.org/10.26623/elektrika.v16i2.8852

Refbacks

  • There are currently no refbacks.


Office: Electrical Engineering Lecturer Room, 7th Floor of Menara USM Building, Universitas Semarang, Jalan Soekarno - Hatta, Tlogosari, Semarang - Central Java Tel:(024) 6702757 Fax: (024) 6702272, Email: elektrika@usm.ac.id

View My Stats

Creative Commons License
This work is licensed under a  Creative Commons Attribution 4.0 International License.