Analisa Perhitungan Nilai Kapsitor Bank untuk Perbaikan Faktor Daya pada PT. Karya Toha Putra

Putri Dwi Lestari, Gunawan Gunawan, Ida Widihastuti

Abstract


The use of electricity with large capacity sometimes faces various kinds of problems. These problems include network losses and voltage drops that occur in the channel. Improvement of electric power factor at PT. Karya Toha Putra is expected to improve the quality of electric power. This improvement is also expected to reduce the cost of electricity bills at PT. Karya Toha Putra. To be able to implement improvements in the quality of the electric power, it is necessary to calculate the reactive power compensated. In this case the power factor to be achieved is 0.95. After doing these calculations, the determination of the capacitor value will be used. By doing these stages, it is expected that the installation of capacitor banks can improve the quality of electric power. Bank capacitors are collections of capacitors used to provide reactive power compensation to improve the electrical power factor. From the results of the study showed that the amount of compensation needed to improve the power factor at PT. Karya Toha Putra is 50 kVAR, divided into 5 steps with one step, a capacitor of 10 kVAR.


Keywords


Electric power quality, Power Factor, Bank Capacitors

Full Text:

PDF

References


R. P. Syawal, Analisis Pengaruh Pemasangan Kapasitor Bank Terhadap Faktor Daya (Studi Kasus Gardu Distribusi Fakultas Teknik Universitas Halu Oleo), 2015.

S. Bandri and T. Danial, Studi Analisa Pemasangan Kapasitor Pada Jaringan Udara Tegangan Menengah 20 KV Terhadap Drop Tegangan (Aplikasi Pada Feeder 7 Pinang GI Muoro Bungo), Tek. Mesin, vol. 4, no. 1, 2014.

P. A. Taufik, Studi Penempatan Kapasitor Untuk Perbaikan Kualitas Tegangan Di Penyulang Kangkung Gi Manggala, 2016.

A. Rochim, Perbaikan Faktor Daya Listrik Dengan Kapasitor Bank Di Greeting Stone Loundry, Universitas Islam Sultan Agung Semarang, 2015.

Nurwolo Agus, "Rancang Bangun Kapasitor Bank Pada Jaringan Listrik Gedung Universitas PGRI Semarang," ISBN 978-60299334-4-4. 2015.

Yani Ahmad, "Pemasangan Kapasitor Bank Untuk Perbaikan Faktor Daya". Journal of Electrical Technology, Vol. 2, No. 3, 2017.

Tampubolon David, Optimalisasi Penggunaan Kapasitor Bank Pada Jaringan 20 KV Dengan Simulasi ETAP . Vol. 9, No. 2, 2014.

M. F. Hakim, Analisis Kebutuhan Capsitor Bank Beserta Implementasinya Untuk Memperbaiki Faktor Daya Listrik Di Politeknik Kota Malang . Jurnal ELTEK , Vol 12, No. 1 2014.




DOI: http://dx.doi.org/10.26623/elektrika.v12i1.2148